Our a-TroniX AX Plus hybrid inverters offer more power and flexibility for large PV systems in households and commercial operations. Thanks to three MPP trackers, they can optimise up to three separate solar arrays independently of each other, which ensures maximum energy yield, especially with differently aligned or partially shaded modules. The AX Plus ensures a stable, future-proof energy supply - for both private homes and commercial enterprises.
download
AX Plus hybrid inverter 3ph data sheet
AX Plus Hybrid Inverter 3ph Operating instructions
AX Plus hybrid inverter warranty conditions
AX Plus Hybrid Inverter 3ph Datasheet
AX Plus hybrid inverter 3ph quick installation
AX Plus inverter factsheet
AX Plus Hybrid Inverter 3ph Quick Installation Guide
Specifications
Specification | AX Plus 5kW | AX Plus 6kW | AX Plus 8kW | AX Plus 10kW | AX Plus 12kW | AX Plus 15kW |
---|---|---|---|---|---|---|
Item number | 9896128 | 9896129 | 9896130 | 9896131 | 9896132 | 9896133 |
PV input | ||||||
Max. Module output [Wp] | 11000 | 14000 | 18000 | 20000 | 24000 | 30000 |
Max. DC input power [W] | 11000 | 13200 | 17600 | 18000 | 22500 | 25000 |
Max. DC voltage [V] | 1000 [1] | |||||
Rated DC operating voltage [V] | 620 | |||||
Max. MPPT input current [A] | 20 / 20 / 20 | |||||
Max. MPPT short-circuit current [A] | 25 / 25 / 25 | |||||
Max. MPPT input power [W] | 10000 / 10000 / 10000 | |||||
Min. operating voltage of the PV system [V] | 90 [2] | |||||
MPPT voltage range [V] | 120 ~ 950 | |||||
Switch-on input voltage [V] | 140 | |||||
Number of MPP trackers | 3 | |||||
Strings per MPP tracker | 1 + 1 + 1 | |||||
Battery | ||||||
Battery type | Lithium battery (LiFePO4) | |||||
Battery voltage [V] | 100 ~ 800 | |||||
Min. operating voltage [V] | 100 | |||||
Min. battery voltage at full AC load [V] | 108 | 125 | 160 | 210 | 250 | 310 |
Max. Charging/discharging current [A] | 50 | |||||
Battery communication modes | CAN | |||||
Output (mains) | ||||||
AC rated power [W] | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 |
Max. apparent AC power [VA] | 5500 | 6600 | 8800 | 11000 [3] | 13200 | 16500 |
Rated mains voltage [V] | 400/230Vac; 380/220Vac, 3L/N/PE | |||||
Rated mains frequency [Hz] | 50/60, ±5 | |||||
Rated AC current [A] (per phase) | 7,6 | 9,1 | 12,1 | 15,2 | 18,2 | 22,7 |
Max. AC current [A] (per phase) | 8,3 | 10 | 13,3 | 16,7 | 20 | 25 |
Power factor | 1 (adjustable from 0.8 cap. to 0.8 ind.) | |||||
Distortion factor (THDI) [%] | <3 at nominal power | |||||
AC input | ||||||
Max. AC power [VA] | 6000 | 7200 | 9600 | 12000 | 14400 | 16000 |
Nominal mains voltage (AC voltage range) [V] | 400/230Vac; 380/220Vac, 3L/N/PE | |||||
Rated mains frequency [Hz] | 50/60, ±5 | |||||
Max. AC current [A] (per phase) | 9,1 | 10,9 | 14,5 | 18,2 | 21,8 | 24,2 |
EPS output | ||||||
Max. apparent AC power [VA] | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 |
Max. apparent AC power [VA] (60s) | 6000 | 7200 | 96000 | 12000 | 14400 | 15000 |
Nominal output voltage [V] | 400/230Vac; 380/220Vac, 3L/N/PE | |||||
Rated mains frequency [Hz] | 50/60 | |||||
Max. EPS current [A] (per phase) | 7,2 | 8,7 | 11,6 | 14,5 | 17,4 | 21,7 |
Power factor | 1 (adjustable from 0.8 cap. to 0.8 ind.) | |||||
Switching time [ms] | <20 | |||||
THDV distortion factor [%] | <3 @linear load | |||||
Efficiency | ||||||
MPPT efficiency [%] | 99,9 | |||||
Max. efficiency [%] | 97,3 | 97,7 | 97,7 | 97,9 | 97,9 | 97,9 |
European efficiency [%] | 97,2 | |||||
Security | ||||||
PV reverse polarity protection | Yes | |||||
Battery reverse polarity protection | Yes | |||||
Anti-islanding protection | Yes | |||||
Short-circuit protection at the output | Yes | |||||
Protection against leakage currents | Yes | |||||
Insulation resistance protection | Yes | |||||
Overvoltage category | lll (AC side), ll (DC side) | |||||
Reverse polarity protection | Yes | |||||
Overcurrent / overtemperature protection | Yes | |||||
DC/AC overvoltage protection | Type ll (PV) / Type ll (AC) | |||||
AFCI protection | Yes | |||||
DC switch | Yes | |||||
General data | ||||||
Dimensions (WxHxD) [mm] | 600×450×226 | |||||
Packaging dimensions (WxHxD) [mm] | 665×545×390 | |||||
Net weight [kg] | 34 | |||||
Gross weight [kg] | 40 | |||||
Installation | Wall-mounted | |||||
Operating temperature range [°C] | -25 ~ +60 | |||||
Storage temperature [°C] | -40 ~ +70 | |||||
Relative humidity during storage/operation [%] | 0 ~ 100 | |||||
Height [m] | <4000 @Derating over 2000 | |||||
Protection class | I | |||||
Protection class | IP65 (for outdoor use) | |||||
Standby consumption [W] | 20 ~ 25 | |||||
Standby mode | Yes | |||||
Cooling | Natural convection cooling | |||||
Volume level [dB] | <40 | |||||
Inverter topology | not isolated | |||||
Communication interface | Ethernet, EMS (RS485), Meter, WLAN (Wifi+LAN+Bluetooth), 4G (optional), DRM, Ripple Control, USB, BMS (CAN), SG Ready | |||||
LCD display | Backlight 16×4 characters | |||||
Standard warranty [years] | 10 | |||||
Operation | 4 × capacitive touch sensor | |||||
Signal transmitter | 1, inside (EPS and earthing fault) | |||||
Certification | VDE 4105; VDE0126; EN 62109; EN61000; EN62920; EN55011; EN IEC 62311; EN301 489; RoHs, REACH, TOR; Belgium C10/11; France EN50549-1; Italy CEI021, CEI0-16 |