
Guarantee conditions
General warranty conditions
Product downloads
Specification
| a-TroniX Hybridpower AX2 3ph | 10 kW 25 | 12 kW 25 | 15 kW 40 | 20 kW 40 |
|---|---|---|---|---|
| Item number | 9889675 | 9889676 | 9889677 | 9889678 |
| Max. Input power (kW) | 15.0 | 18.0 | 22.5 | 30.0 |
| Switch-on voltage (V DC) | 135 | |||
| Max. Input voltage (V DC) | 1000 | |||
| Nominal input voltage (V DC) | 620 | |||
| MPPT voltage range (V) | 200-950 | |||
| Number of MPP trackers | 2 | |||
| Number of PV inputs | 1/1 | 1/1 | 2/2 | 2/2 |
| Max. Input current (A) | 15/15 | 15/15 | 30/30 | 30/30 |
| Max. Short-circuit current (A) | 20/20 | 20/20 | 40/40 | 40/40 |
| Battery type | Lithium battery (with BMS) | |||
| Battery communication mode | CAN / RS485 | |||
| Battery voltage range (V DC) | 135 – 750 | |||
| Max. Charging/discharging current (A) | 25/25 | 25/25 | 40/40 | 40/40 |
| Rated output power (kW) | 10.0 | 12.0 | 15.0 | 20.0 |
| Max. Output power (kW) | 5,5 | 8,8 | 11 | 13,2 |
| Max. Charging power of the battery (kW) | 10 | 12 | 15 | 20 |
| Nominal output voltage (V AC) | 3L / N / PE, 230 (400) | |||
| AC nominal frequency (Hz) | 50/60 | |||
| Max. Output current (A) | 16,5 | 20 | 25 | 33,5 |
| Power factor | 0.8 leading ... 0.8 lagging | |||
| Max. Total harmonic distortion | <3% @rated output power | |||
| DCI | <0.50% ln | |||
| UPS switching time (ms) | <10 | |||
| Nominal output voltage (V AC) Backup | 3/N/PE, 230 (400) | |||
| AC nominal frequency (Hz) Backup | 50/60 | |||
| Max. Apparent output power (kVA) | 11 | 13,2 | 16,5 | 22 |
| Peak apparent power at overload (kVA) / (s) | 20,60s | 25,60s | — | — |
| Single-phase peak output power (kVA) | 2,1 (*3) | 3,3 (*3) | 4 (*3) | 5 (*3) |
| Voltage harmonic distortion | <3% @Linear load | |||
| Max. Efficiency % | 98,20% | 98,40% | — | — |
| European efficiency % | 97,40% | 97,50% | ||
| DC reverse polarity protection | Integrated | |||
| Protection against reverse polarity of the battery input | Integrated | |||
| Protection against insulation resistance | Integrated | |||
| Overvoltage protection | Integrated | |||
| Overheating protection | Integrated | |||
| Residual current protection | Integrated | |||
| Island formation protection | Integrated | |||
| AC overvoltage protection | Integrated | |||
| Overload protection | Integrated | |||
| AC short-circuit protection | Integrated | |||
| Overvoltage category PV: II; Main: III | PV: II; Main: III | |||
| Dimensions (mm) W*H*D | 534*418*210 | |||
| Weight (kg) | 27 | |||
| Protection class | IP65 | |||
| Self-consumption at night (W) | <15 | |||
| Topology | Transformerless | |||
| Operating temperature range (°C) | -30 – +60 | |||
| Relative humidity (%) | 0 – 100 | |||
| Max. Operating height (m) | 3000 | |||
| Cooling | Natural air circulation | |||
| Noise level (dB) | <25 | |||
| Display | OLED & LED | |||
| Communication | CAN, RS485, WiFi / LAN (optional) | |||
| Certifications | EN 55011:2016/A2:2021; CISPR 11:2015/AMD2:2019; EN IEC 6100-6-1; EN IEC 61000-6-2; EN IEC 61000-6-3; EN IEC 61000-6-4;EN IEC 61000-3-2; EN IEC 61000-3-11; IEC 61000-3-12; EN 61000-3-3; IEC 61000-3-3; IEC 62109-1; IEC 62109-2; EN 62109-2; VDE-AR-N 4105;IEC 62321:2013 RoHS Directive; REACH-SVHC 225 (EC) | |||